Saturday, February 22, 2014

Fukushima updates - February 22 - 23 , 2014 Weekend thread - another Tepco screw up allows for another huge release of contaminated water , updates on contamination in Japan and North America ....WIPP Plutonium release at US nuclear facility , roof collapse , serious breach , related to seismic event ? Remind anyone of the non information in Japan regarding Fukushima ?

Energy News......

Japan.....



Nuclear Professor: Fish on West Coast found with Fukushima radioactive material — We’re testing fish that are sold at markets to U.S. consumers (AUDIO)

NHK: Failure at Fukushima — Gundersen: Extraordinarily radioactive leak will be in Pacific shortly; “Site is going to bleed into ocean for 100 years”

TV: It’s a “record-high” leak at Fukushima, extraordinarily radioactive — Almost 8,000,000 times limit — Even more toxic since it was from early in disaster — Alarm went off 9 hours before, but disregarded — Now checking for other leaks — “News came as a shock” (VIDEO)

New Analysis: Radiation levels “much greater” than anything expected from Fukushima says Navy expert — 2,500 pCi/m³ of particulate detected; Would be several times higher if gases included — CNN: Do the experts know everything that went on at Fukushima? (VIDEO)




US / Canada ......



U.S. Gov’t-funded Study: West Coast and Hawaii residents are Fukushima downwinders — Effects of this radiation exposure expected to be ‘beneficial’

Canadian Gov’t: “There’s going to be radiation from Fukushima for years to come… Testing will never stop” — US Gov’t: There’s no reason to believe radioactive plume coming to West Coast

TV: Radioactive waste containers may be “smashed and opened” after roof collapse at leaking U.S. nuclear site — Official: We believe there’s been a breach… “It’s a very serious thing” — ‘Seismic event’ mentioned — High levels of alpha and beta radiation detected (VIDEO)

Plutonium release at U.S. nuclear facility: “We don’t know what happened… don’t know whether it could happen again” — “Big problem is…how much is continuing to be released?” — Officials “know very little about extent of problem or how to solve it”

Airborne plutonium detected outside troubled U.S. nuclear facility — Expert: ‘Radiation event’ appears to have occurred, leading to a release; “Levels are highest ever detected” around site



EX SKF.......


FRIDAY, FEBRUARY 21, 2014

(UPDATED with Photos) #Fukushima I NPP: TEPCO Thinks Someone Opened the Wrong Valve, Causing the Leak of 100 Tonnes of RO Waste Water with 23 Terabecquerels of All-Beta


(UPDATE) One of the local papers in Fukushima Prefecture shares my suspicion that someone (possibly plural) tried to hide the mistakeFukushima Minyu(2/22/2014; part):
実際は最大9時間は開いていたとみられることを明らかにした。弁の操作を誤った可能性があり、さらに、現場でミスを隠そうとした可能性も出てきた。発覚後の20日未明の現場確認では問題の弁は閉まっていたが、前日の19日午前11時ごろの写真では弁が開いた状態で、通常は外しておく開閉操作用レバーが取り付けられていた。

[TEPCO] disclosed [on February 21] that the valve in question was in fact open for 9 hours at the maximum. There is a possiblity that someone made a mistake in operating the valve. Further, there is a possibility that they [those in the section in charge of the water transfer operation] tried to hide the mistake. In the early hours of February 20 after the leak was discovered, the valve in question was confirmed to be closed. However, in the photo taken around 11AM on the previous day (February 19) the valve was open, and the lever to open and close the valve was attached to the valve, which is normally removed.

From TEPCO's photos and videos library, 2/21/2014:

The valve in question (V347) on February 19, 2014 morning, "open" position, as it shouldn't:

The same valve on February 20, 2014, "closed" position, as it should, but after the leak:

==========================

That's what increasingly the government public relations broadcaster aka NHK says. NHK also says TEPCO has dispatched investigators from the TEPCO headquarters (in Tokyo) to Fukushima I Nuclear Power Plant and started interviewing the plant workers.

It is rather difficult to grasp what NHK is trying to say (they do talk like TEPCO's PR), but I think they are saying:
1. The RO waste water was to be transferred to a storage tank that was NOT the tank it subsequently went and overflowed.

2. Someone opened the wrong valve, and the water went to the wrong tank which was almost full. The water leaked from the top of the tank.

3. AFTER the water leaked from the wrong tank, he realized his mistake; he closed that valve, and opened the valve that should have been opened to transfer the contaminated water to the correct tank.

A gross human error (I hope), which caused (at least) 100 tonnes of extremely contaminated (230 million Bq/L of all-beta, or 23 trillion Bq (terabecquerel) in 100 tonnes) water to leak (see my post on 2/20/2014).

According to Mainichi Shinbun, the Nuclear Regulation Authority has said it is speaking with IAEA on whether to have an INES event scale assigned to this particular incident. The last year's leak of 300 tonnes of the same RO waste water from the storage tanks into the surrounding soil was INES Level 3 "incident". (Level 4 and above are "accidents".)

From NHK News (2/22/2014; emphasis is mine):
汚染水流出 誰かが配管の弁を開けたか

Contaminated water leak: Did someone open the valve?

東京電力福島第一原子力発電所で、山側のタンクから高濃度の汚染水およそ100トンが流出した問題で、東京電力は本来、閉じている配管の弁を誰かが開けたのが原因とみて、本店の調査の担当者を派遣して作業員への聞き取りを進めています。

Regarding the 100 tonnes of highly contaminated water that leaked from a tank at Fukushima I Nuclear Power Plant, TEPCO has dispatched investigators from the TEPCO headquarters to the plant who are interviewing the workers. TEPCO suspects someone opened the valve that should remain closed, causing the leak.

福島第一原発では今月19日から20日にかけて4号機の山側にあるタンクに水が入りすぎ、汚染水およそ100トンが敷地内の地面に流出しました。

At Fukushima I Nuclear Power Plant, about 100 tonnes of contaminated water leaked into the surrounding ground in the plant compound in February 19 and 20 when too much water was poured into a tank on the mountain-side (west) of Reactor 4.

当初、東京電力は、汚染水の処理設備から問題のタンクにつながる配管の途中の弁の1つが、閉じた状態になっていたにもかかわらず、水が流れていたとして、この弁が故障していた疑いがあると説明していました。

Initially, TEPCO explained that one of the valves [there are three] on the pipe that goes to this tank may have malfunctioned, as it let the water flow even if it was closed.

ところが、別の作業で弁を撮影した写真が見つかり、水を断続的に移送していた今月19日の午前の時点では、故障の疑いがあるとされた弁は開いた状態になっていたことが分かりました。

However, a photograph was found that captured the same valve on a different job; the photo showed that the valve, suspected of malfunctioning, was open as of the morning of February 19 when the water was being transferred intermittently.
一方、本来、汚染水を送る予定だったタンクにつながる配管の弁は19日の午前の時点では閉じられ、水が流れないようになっていて漏えいが見つかったあとには開いていました。

On the other hand, the valve on the pipe that goes to the tank where the contaminated water was supposed to go remained closed as of the morning of February 19, blocking the water flow. However, after the leak was found, this valve was open.

東京電力はこの2つの弁を誰かが開け閉めしたことが汚染水が漏れた原因とみています。

TEPCO thinks someone opened and closed these two valves, causing the leak of the contaminated water.

弁が操作された理由や詳しい経緯を明らかにするため、東京電力は本店の調査の担当者を派遣して作業員から聞き取りを進めています。

In order to find out the details of how the incident happened and why the valves were operated, TEPCO has sent investigators from the headquarters to the plant who are interviewing the workers.

今回の問題で東京電力は弁を操作した際のタンクの水位の監視が徹底されておらず、弁の開け閉めに使う器具がふだん誰でも使える状態で置かれていたことから管理の見直しを検討しています。

TEPCO is considering a review of the maintenance/operation procedure, as the water level monitoring procedure when valves were operated was not strictly followed and the tools to open and close the valves were readily available to anyone.

(Hmmm. So TEPCO does suspect someone may have done it on purpose?)

For now, it looks like some worker made a mistake, and after the leak corrected the mistake without saying anything to anyone, hoping no one would notice.

Too bad TEPCO found the photos...



THURSDAY, FEBRUARY 20, 2014

#Fukushima I NPP: 23,000,000,000,000 Bq (or 23 Terabecquerels) of All-Beta in 100 Tonnes of Waste Water that Leaked from Top of Storage Tank


(UPDATE 2/21/2014) Someone may have opened the wrong valve, not the valve malfunctioning as initially claimed by TEPCO, causing the leak. See my latest post.

=======================

According to TEPCO's alert for the press (2/20/2014), there has been a fresh leak of highly contaminated RO (reverse osmosis) waste water at Fukushima I Nuclear Power Plant, the same kind of water that was found leaking in August 2013.

The densities of radionuclides in the highly contaminated water that was found leaking on February 19, 2014 from the top of a tank that stores waste water after reverse osmosis treatment are:
Cesium-134: 3,800 Bq/L
Cesium-137: 9,300 Bq/L
Cobalt-60: 1,800 Bq/L
Manganese-54: 1,300 Bq/L
Antimony-125: 41,000 Bq/L
All-beta: 230,000,000 Bq/L

There are 1,000 liters per tonne, and TEPCO says about 100 tonnes of this water leaked.

So, in the 100 tonnes of water, there are:
23,000,000,000,000 Bq, or 23 terabecquerels of all-beta (including strontium-90)

How did this happen? It was not through some cracks or loose rivets with deteriorating packing this time.

The short answer is: TEPCO let it overflow by negligence.

The longer answer, as I extract from TEPCO's photos and videos library (2/20/2014) document:

1. The tank is a tall, riveted tank to store RO waste water in H6 area. The tank was almost full.

2. For some unknown reason, the valves of the pipe that feeds RO waste water to the tank were open, which should have been closed. The waste water kept coming and filling the tank.

3. At 2:01PM on February 19, 2014, an alarm went off, indicating the water level is dangerously high.

4. But there was no transfer of the water scheduled at that time. So TEPCO and the workers thought either the alarm was malfunctioning or the water gauge was malfunctioning. They did nothing.

5. The waste water started to overflow from the flange at the top of the tank.

6. The waste water flowed into the rain gutter installed on the perimeter of the tank top to collect rainwater.

7. The gutter is connected to a drainpipe to guide rainwater OUTSIDE the dam that surrounds the concrete pad on which the tanks stand.

8. The extremely contaminated waste water flowed through the drainpipe onto the ground.

9. Finally a worker from a TEPCO affiliate company found the leak during a patrol at 11:25PM on February 19, 2014.

10. The water stopped at 5:40AM on February 20, 2014 after the valves were closed.

The ground outside the dam looks well-saturated:




Simply Info......

WIPP.....


WIPP Plutonium Leak May Have Been From Ceiling Collapse

WIPP Plutonium Leak May Have Been From Ceiling Collapse
Officials are considering a ceiling collapse that crushed radioactive waste barrels containing plutonium as a possible cause for the radiation leak detected almost a week ago at the WIPP facility. The head of the facility admitted they think a container has been breached. “Franco said indications suggest a drum or drums containing radioactive waste may have breached for reasons that are not yet known.” One possible cause officials gave to the press was that the ceiling in the … Read entire article »


WIPP Underground Investigation Being Planned, Failure Area Identifed

WIPP Underground Investigation Being Planned, Failure Area Identifed
Federal representatives reported that a joint investigation is underway to establish a plan to enter WIPP’s underground facilities. They gave no timeline for entry. The location of the leak is “downwind” of panel 7, room 7. This hints the incident could have happened in panel 7 where current work to store waste is underway. DOE claims the earlier truck fire was … Read entire article »








WIPP Plutonium Leak Amount Confirmed

WIPP Plutonium Leak Amount Confirmed
CEMRC, the New Mexico authority that monitors outside the WIPP plutonium facility has provided some usable readings for the leaks. CEMRC found at the filter 1/2 mile offsite from WIPP: 0.64 Bq of Americium 241 0.092 Bq of Plutonium 239+240 These are assumed to be in meters squared (m3) since that is the unit CEMRC has used for previous readings. CEMRC readings from dates before … Read entire article »








Japan......


Nuclear Establishment Takes Over Fukushima Medical University

Nuclear Establishment Takes Over Fukushima Medical University
More agreements have been inked between Fukushima Medical University and the international nuclear mafia. Fukushima Medical University has signed an agreement with the ICRP to join their work. ICRP is largely funded and run by various governmental nuclear regulators and the nuclear industry. (List of ICRP Commission members). Fukushima Medical University also created visiting professor positions for some IAEA staff. While the … Read entire article »






23 Tbq Water Leak At Fukushima Caused By Multiple Human Errors

23 Tbq Water Leak At Fukushima Caused By Multiple Human Errors
100 tons of water leaked from a contaminated water tank at Fukushima Daiichi after workers incorrectly aligned valves. They then ignored the alarm that alerted them to a tank that was not supposed to be filling, had overfilled. After the tank spilled out over the top flange the water then leaked out through a failure in the water weir that … Read entire article »








Fukushima Unit 2 Loses Reactor Thermometer

Fukushima Unit 2 Loses Reactor Thermometer
Unit 2 at Fukushima Daiichi has lost another bottom thermometer in the reactor vessel. Workers said it short circuited when they were testing it. This leaves one thermometer remaining to estimate temperature in the bottom of the reactor vessel. Accurate temperatures inside unit 2 have been an ongoing problem. UPDATE: TEPCO reports workers short circuited the thermometer when they put the wrong … Read entire article »








Fukushima Brings New Awareness Of Contaminated Food Worldwide

Fukushima Brings New Awareness Of Contaminated Food Worldwide
The concerns about food contamination from Fukushima has also increased awareness of the lingering problems of world wide food contamination from various sources. Fukushima was not the first major radiation release to the environment. Atomic testing in the Pacific contributed to considerable amounts of radioactive contamination of the sea that can still be found in sea life today. Chernobyl contaminated … Read entire article »










High Levels Of Radiation Found In Fukushima Unit 3 Turbine Building

High Levels Of Radiation Found In Fukushima Unit 3 Turbine Building
TEPCO released radiation readings for water inside the unit 3 turbine building this week. The readings were from December 2013. TEPCO used them as a comparison to show a water leak elsewhere in the building was not reactor water. The readings themselves are a rare find as TEPCO doesn’t usually release this data. The readings are disturbingly high. Reference: No. 3 … Read entire article »





No comments: